Surgical Supplies 624 Views 26 June 2020
For details of taboo content or precautions, please refer to the instruction manual
Disposable linear cutting stapler for endoscopic is suitable for various open or minimally invasive surgery to perform transection, excision or anastomosis of tissue.
Registration number of linear cutting stapler for disposable endoscopes: Su Machinery Note 20182021410
Approval number for linear cutting stapler/ad review for disposable endoscope: Su Jiguang (text) No. 2019083325
Production license number: Su food and drug supervision equipment production permit No. 20180145
Model specifications |
Suture length(mm) | Staple height(mm) |
YDN50 | / |
/ |
YDN150 | / |
/ |
YDN200 | / |
/ |
YDNW30*2.5 | 30 |
2.5 |
YDNZ30*2.5 | 30 |
2.5 |
YDNZ30*3.5 | 30 |
3.5 |
YDNZ45*2.5 | 45 |
2.5 |
YDNZ45*3.5 | 45 |
3.5 |
YDNZ45*4.5 | 45 |
4.5 |
YDNZ60*2.5 | 60 |
2.5 |
YDNZ60*3.5 | 60 |
3.5 |
YDNZ60*4.5 | 60 |
4.5 |
YDNW30*3.5 | 30 |
3.5 |
YDNW45*2.5 | 45 |
2.5 |
YDNW45*3.5 | 45 |
3.5 |
YDNW45*4.5 | 45 |
4.5 |
YDNW60*2.5 | 60 |
2.5 |
YDNW60*3.5 | 60 |
3.5 |
YDNW60*4.5 | 60 |
4.5 |
YDN: Gun body
YDNZ: Generation components
YDNW: Second generation components
New stitching arrangement
When firing, 6 rows of staples are released, and the cutting knife passes through the middle to give tissue suture guarantee;
The height of the three rows of staples on one side is more different (step design), the blood supply of the suture tissue is good, and the cutting edge is good for hemostasis.
Instrument link and operating lever
Wild with 30mm, 45mm and 60mm staple cartridges;
The short rod is suitable for open surgery, the general rod is suitable for ordinary endoscopic, and the long rod is suitable for surgery with a particularly thick abdominal wall;
The operating lever can rotate 360°.
Component joint head
The design of the joint head has three adjustment angles of 0°, 30° and 45°, which is convenient for operation at a suitable angle;
Three types of staple cartridges with lengths of 30mm, 45mm and 60mm, each containing 5 staple cartridges, suitable for cutting and stitching 0.7-2.0mm thickness tissue, reducing the complexity of operation;
With no damage pre-holding force, it can be used as a grasping forceps to reduce the number of instrument replacement;
Reduce tissue side overflow and end overflow during firing.
Design of fixed nail cutting board
The front opening of the wide nail box is convenient for organization;
The nail cutting board is thin and fixed, and it can enter smoothly without separating the large wind gap, reducing tissue damage;
When the tissue is clamped, the vision is better.
Indicator line of cutter head
It is convenient to grasp the position of the cutter head under the mirror